The following case studies PROVE that energy efficiency does not discriminate! Energy efficient upgrades are needed for newer custom homes as well as older homes! The following is very representative of the situations that we encounter everyday!
Helful terms:
ACHn – Natural Air Changes per Hour
Case History #1
House Square
HVAC System 1 149 CFM loss – 14.9%
HVAC System 2 788 CFM loss – 39.4%
This 2 story house is located in NW Austin. All bedrooms and the home office are upstairs and the owner complained that the upstairs area is too warm in the summer and too cool in the winter. The system has a pre-test duct leakage of 60.7%. The natural air changes per hour ACHn registered .483, exceeding the recommend level of .35 to .45 to optimize balancing health and energy efficiency. After our work, we reduced the leakage to 7.07% and reduced the ACHn to .422. (natural air changes per hour)
System 1 – 751 CFM
Total recaptured CFM
751 CFM (this is equivalent to conditioning 4 ½ extra rooms delivering 160 CFM per room). This is significant considering the size of the house and that all bedrooms are upstairs!
House Square
Pre-Test Measurements
Post-Test Measurement
HVAC System 1 99 CFM loss – 7.07%
Case History #3
This house is located in South Austin in an established neighborhood. The owners complained of high utility bills and air distribution problems. The owners contacted us to install radiant barrier and attic insulation. The attic insulation was just fine, and all they needed was more ventilation in the attic roof with no need for radiant barrier. However, they did have significant air infiltration issues and duct leakage. Initailly, they had duct leakage of 26.9% and their ACHn was .719, a staggering number! We were able to tighten their house to where their ACHn was .39, a remarkable result!
Recaptured CFM after energy efficient improvements:
System 1 – 228 CFM
House square footage - 1957
Pre-Test Measurements
HVAC System 1 323 CFM loss – 26.9%
Post-Test Measurement
HVAC System 1 98 CFM loss – 7.9%